  •   What

      External quench on atmospheric side of seal

      Quench fluids typically steam ,nitrogen ,or water .

      Why

      Prevent solids buildup on atmospheric side of seal .

      Prevent icing

      Where

      Used with single seals .

      Oxidizing fluids or fluids that coke ,hot hydrocarbons .

      Crystallizing fluids or fluids that salt out .

      Caustic .

      Cold fluids less than (32F)

      Preventative Maintenance

      Quench inlet should on top of gland with outlet /drainon

      bottom .

      Quench pressure should be limited to 0.2 bar ( 3psi )or less

      Use throttle bushing on atmospheric side of seal to direct

      quench flow to seal drain .

      Monitor regularly ,checking for closed valves ,blocked lines ,

      and steam trap condition .