What
Seal flush from pump discharge through cyclone separator
Centrifuged solids are returned to pump suction .
Why
Seal chamber heat removal .
Solids removal from flush and seal chamber .
Where
Dirty or contaminated fluids ,water with sand or pipe slag
Non-polymerizing fluids
Preventative Maintenance
Cyclone separator works best on solids with a specific gravity
twice the process
Seal chamber pressure must be nearly equal to suction
pressure for proper flows
Piping should not include an orifice and is not expected to
vent the seal chamber .
Typical failure mode is clogged separator or pipes - check
temperatures at pipe ends .